    Voltar ao status atual

    Questões de rede no local de Frankfurt

    Início 27 Gwengolo 2026 da 23:52 UTC · 14h 43m

    OutageMajor incident
    Componentes afetados
    Core Network
    1. 27 Gwengolo 2026 da 23:59 UTCinvestigating

      Atualmente, estamos vivenciando problemas de rede que afetam a acessibilidade da nossa rede localizada em Frankfurt. Nós forneceremos atualizações nesta página de status o mais rapidamente possível.

    2. 28 Gwengolo 2026 da 00:23 UTCmonitoring

      Desde 00:05 UTC, todos os serviços em nossa localização em Frankfurt são totalmente alcançáveis novamente. A causa foi a falha de um motor de roteamento num dos nossos roteadores. O motor de roteamento redundante assumiu automaticamente. Durante a transição, a acessibilidade da nossa rede de Frankfurt foi afectada entre aprox. 23:52 e 00:05 UTC. A rede está atualmente funcionando de forma estável no motor de roteamento redundante. Estamos a trabalhar no restabelecimento da componente falhada e continuamos a acompanhar de perto a situação. Nós forneceremos uma atualização adicional uma vez que a redundância total tenha sido restaurada.

    3. 28 Gwengolo 2026 da 21:31 UTCresolved

      Este incidente foi resolvido.

    Traduzido automaticamente da atualização oficial do incidente.

    Zurich: Network Connectivity Issues

    Início 11 Eost 2026 da 17:30 UTC · 2h 31m

    IssuesMinor incident
    Componentes afetados
    Core Network
    1. 11 Eost 2026 da 18:07 UTCinvestigating

      Our upstream provider at our Zurich cloud environment, has confirmed network issues. They are currently investigating and we will provide updates as soon as available here. Link to our upstream‘s status page: https://status.nine.ch/

    2. 11 Eost 2026 da 20:01 UTCresolved

      We have been informed that the incident is resolved since 9.06pm.

    Perda de pacotes em certos hipervisores

    Início 22 Gouere 2026 da 09:20 UTC · 7h 55m

    IssuesMinor incident
    Componentes afetados
    Cloud server hosts
    1. 22 Gouere 2026 da 09:20 UTCinvestigating

      Estamos actualmente a investigar esta questão.

    2. 22 Gouere 2026 da 10:00 UTCidentified

      A questão foi identificada e está a ser implementada uma solução.

    3. 22 Gouere 2026 da 17:15 UTCresolved

      O incidente foi totalmente resolvido.

    Traduzido automaticamente da atualização oficial do incidente.

    Brief network disturbance in Frankfurt (FRA) during scheduled maintenance

    Início 23 Mezheven 2026 da 16:40 UTC · 0m

    OutageMajor incident
    1. 24 Mezheven 2026 da 09:01 UTCresolved

      During scheduled maintenance on our network infrastructure on Jun 23, 2026, one of our edge routers in Frankfurt (FRA) became temporarily unavailable by a software overload. This caused a network interruption of approximately one minute, until the second edge router fully took over the routing and connectivity was restored. Although the maintenance was announced, no service impact was expected. The disturbance was briefly wider than the announced scope, affecting connectivity for most of services in the Frankfurt location rather than only the one announced VLAN. We stopped the change immediately and have paused the remaining maintenance while we review the underlying causes, so the work can be completed reliably. We apologize for the any circumstances.

    Upstream packet loss

    Início 19 Mezheven 2026 da 09:46 UTC · 2h 49m

    Pending
    Componentes afetados
    Core Network
    1. 19 Mezheven 2026 da 09:46 UTCidentified

      We have identified packet loss to one of our upstream providers, routes have been switched. We will be monitoring the situation.

    2. 19 Mezheven 2026 da 12:36 UTCresolved

      The issue was caused by unstable firmware on the core router of one of our upstream providers. The firmware has now been updated, and the routes have been returned to their previous state.

    Info: DENIC Outage

    Início 5 Mae 2026 da 21:41 UTC · 9h 54m

    OutageCritical incident
    Componentes afetados
    DENIC
    1. 5 Mae 2026 da 21:41 UTCidentified

      The DENIC is currently experiencing a major issue causing all .de Domains to become unresolvable after dns caches run out. DENIC Statuspage: https://status.denic.de/pages/incident/592577eab611ce1e0d00046f/69fa60ef9d12f5057a974f38

    2. 6 Mae 2026 da 07:35 UTCresolved

      This incident has been resolved.

    Service degration at ZRH1 (Zurich datacenter)

    Início 12 Meurzh 2026 da 17:21 UTC · 3m

    IssuesMinor incident
    Componentes afetados
    Cloud server hosts
    1. 12 Meurzh 2026 da 17:21 UTCinvestigating

      During routine maintenance work, we encountered a service degration at our Zurich datacenter, which affects one hypervisor and the VM's running on it. We are currently investigating this issue and keep you updated here.

    2. 12 Meurzh 2026 da 17:30 UTCresolved

      The issue has been identified and resolved.

    MySQL database outage

    Início 10 Meurzh 2026 da 10:13 UTC · 2h 2m

    OutageCritical incident
    Componentes afetados
    Cloud server hosts
    1. 10 Meurzh 2026 da 12:23 UTCinvestigating

      At March 10, 2026, 11:13 AM, our monitoring alerted that the customer MySQL database was not available. The issue affects managed web hosting services which are operated within our Kubernetes clusters.

    2. 10 Meurzh 2026 da 12:24 UTCinvestigating

      We are still investigating an issue with the VM's running the database.

    3. 10 Meurzh 2026 da 12:54 UTCresolved

      The incident has been resolved and the environments are all available again. We will provide further information with our postmortem.

    Packet-loss during SDN configuration changes

    Início 7 Meurzh 2026 da 22:00 UTC · 16m

    Pending
    1. 10 Meurzh 2026 da 14:29 UTCresolved

      We encountered packet loss on virtual machines during a network reload in our virtualization environment when provisioning new SDN settings. The issue was resolved by March 8, 2026, 0:30. Moving forward, we will implement measures to ensure that network reloads do not cause packet loss. We will therefore announce the according maintenance frame here on the statuspage.

    Network outage

    Início 16 Cʼhwevrer 2026 da 18:15 UTC · 1h 16m

    OutageCritical incident
    Componentes afetados
    Core Network
    1. 16 Cʼhwevrer 2026 da 18:19 UTCinvestigating

      We are currently experiencing a network outage at our location in Frankfurt. We are currently investigating and provide updates on this page as soon as possible.

    2. 16 Cʼhwevrer 2026 da 18:30 UTCidentified

      The network is available again since 19:24 CET. We continue investigating and analyzing the route cause.

    3. 17 Cʼhwevrer 2026 da 09:15 UTCresolved

      The incident has been resolved and no further impact is expected. We will provide details today afternoon.

    4. 17 Cʼhwevrer 2026 da 17:48 UTCpostmortem

      On February 16, 2026, an incident identified as INC-262 occurred, resulting in a critical network outage that affected all systems in our Frankfurt data centers for a duration of 8 minutes. The incident was triggered by a routine configuration change made to a static route on one of our routers. Prior to implementation, the configuration underwent validation via the operating system \(Juniper Junos OS\), which generally checks for errors. However, due to a bug in the firmware, the system incorrectly accepted a faulty configuration change. 4 minutes after the change was applied, both forwarding engines were reported unreachable by the routing engine. The issue was promptly detected and reported by our monitoring systems. An automatic rollback occurred one minute following the failure due to a lack of manual confirmation, which restored both routing engines and forwarding engines. Safety mechanisms have worked as expected and resulted in a quick recovery completed by 7:27 PM. To preemptively harden our infrastructure against similar issues in the future, we already planned to transition from a redundant routing chassis to completely isolated devices, ensuring full redundancy even in case of such failures. This transition is scheduled for April/May during a planned maintenance. We appreciate your understanding and patience as we work to enhance our systems' reliability.

    Degraded connectivity between our locations at FRA and ZUR

    Início 11 Cʼhwevrer 2026 da 12:30 UTC · 0m

    IssuesMinor incident
    1. 11 Cʼhwevrer 2026 da 13:51 UTCresolved

      At 1:28PM the connection between our locations in Frankfurt and Zurich become degraded since one gateway at our upstreams becomes unavailable. The issue was resolved by 1:49PM completely by changing the gateway's configuration and adapting to the new configuration. Moving forward, we will check for possible improvements to enhance network resilience.

    Packet-loss on carrier-level

    Início 23 Genver 2026 da 08:00 UTC · 0m

    IssuesMinor incident
    1. 23 Genver 2026 da 12:00 UTCresolved

      Starting this morning, we have detected packet loss occurring a few times for a few seconds at carrier level. Our analysis revealed that this is related to incoming or outgoing traffic via Liberty Global (AS6830). As a mitigation measure, we have deactivated this carrier and are using alternative routes. We will monitor the situation closely and wait for a response before reactivating the carrier.

    Upstream BGP Session Restart (No Impact)

    Início 26 Du 2025 da 09:50 UTC · 1h 0m

    Pending
    1. 26 Du 2025 da 11:09 UTCresolved

      One of our upstreams was experiencing network issues for about 5 minutes. Redundancy was working as expected and there was no noticeable impact.

    Hardware network link failure in FRA-2

    Início 11 Du 2025 da 11:34 UTC · 1h 0m

    Pending
    1. 11 Du 2025 da 13:11 UTCresolved

      A physical network connection inside our network in our FRA-2 location failed causing packet loss and a disturbance of multiple services. All our links are setup redundantly and the redundancy automatically took over within a few seconds.

    Packet loss via routes of AS48314

    Início 4 Here 2025 da 11:51 UTC · 29m

    Pending
    Componentes afetados
    Core Network
    1. 4 Here 2025 da 12:17 UTCinvestigating

      One of our uplink providers, IP-Projects (AS48314), is experiencing a network attack. This have lead to packet loss for max. five minutes, starting from 11.42. We have deactivated incoming and outgoing till the network is stable again there. Link to our uplink's status page entry: https://status.ip-projects.de/?page=Issue&id=551

    2. 5 Here 2025 da 22:16 UTCresolved

      This incident has been resolved.

    Network disturbance during active DDoS mitigation

    Início 23 Gouere 2025 da 07:00 UTC · 0m

    Pending
    1. 23 Gouere 2025 da 14:13 UTCresolved

      From 22 July 2025 10pm to 23 July 2025 1.30pm, some customers using our DDoS Protected IP-Transit service experienced connectivity issues during active DDoS mitigation. This was due to an incorrect routing configuration by one of our upstream providers. The incident affected IP addresses with active DDoS mitigations during the mitigation period for the attack (typically 30 minutes). The majority of our services remained operational throughout this period. We resolved the issue by extending our routing policies and working with our provider to prevent this configuration problem from recurring. We apologize for any inconvenience this may have caused.

    DNS resolution issues caused by Cloudflare DNS unavailability

    Início 14 Gouere 2025 da 22:06 UTC · 1h 13m

    IssuesMinor incident
    Componentes afetados
    Core Network
    1. 14 Gouere 2025 da 22:06 UTCinvestigating

      We are seeing issues regarding routes to Cloudflare, we're investigating and will update you as soon as we have further information.

    2. 14 Gouere 2025 da 22:11 UTCidentified

      We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it.

    3. 14 Gouere 2025 da 22:14 UTCidentified

      We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it. Cloudflare has posted the incident on their statuspage: https://www.cloudflarestatus.com/incidents/28r0vbbxsh8f

    4. 15 Gouere 2025 da 07:12 UTCidentified

      We continuing to monitor

    5. 15 Gouere 2025 da 07:13 UTCresolved

      The incident has been resolved by Cloudflare

    Network disturbance at FRA01

    Início 2 Ebrel 2025 da 13:00 UTC · 8h 27m

    OutageCritical incident
    Componentes afetados
    Core Network
    1. 2 Ebrel 2025 da 13:11 UTCinvestigating

      We are currently experiencing network issues at our Frankfurt locations.

    2. 2 Ebrel 2025 da 13:24 UTCmonitoring

      The network issue has been fixed and our network is stable again. We keep monitoring and will provide updates here.

    3. 2 Ebrel 2025 da 21:27 UTCresolved

      This incident has been resolved.

    4. 2 Ebrel 2025 da 21:27 UTCpostmortem

      At approximately 15:00 CET on April 2nd, 2025, we experienced a brief network disruption affecting our Frankfurt \(FRA\) infrastructure. The incident occurred during a scheduled maintenance window for one of our upstream providers. The network disruption lasted for approximately seven minutes, during which some of our services experienced reduced accessibility. Our network engineering team identified the issue immediately and implemented necessary measures to restore service stability. While we typically handle such maintenance windows without any customer impact, this particular incident resulted in a brief service interruption. We have conducted a thorough review of our maintenance procedures and will be implementing additional safeguards to prevent similar incidents in the future. We understand the impact this may have had on your operations and apologize for any inconvenience caused. Our team remains committed to providing reliable service and continuous improvement of our infrastructure management processes. If you have any questions or concerns, please don't hesitate to reach out to us.

    Major outage of our compute infrastructure in FRA-2

    Início 5 Kerzu 2024 da 13:54 UTC · 19h 47m

    OutageCritical incident
    Componentes afetados
    Cloud server hosts
    1. 5 Kerzu 2024 da 13:54 UTCinvestigating

      We're currently experiencing a major outage on our compute infrastructure in our FRA-2 location. We're investigating the issue and will provide additional information soon

    2. 5 Kerzu 2024 da 14:22 UTCidentified

      We've identified the issue and are working on recovering all services ASAP

    3. 5 Kerzu 2024 da 14:27 UTCidentified

      We are currently booting all affected servers again. The services will be back online in the next minutes.

    4. 5 Kerzu 2024 da 18:00 UTCmonitoring

      We brought all services back up and are closely monitoring them

    5. 5 Kerzu 2024 da 22:14 UTCmonitoring

      All services are running as expected again. We will keep monitoring and let the incident open till we publish an official statement tomorrow.

    6. 6 Kerzu 2024 da 09:40 UTCresolved

      All systems and services have been stable since the recovery and the normal operational state has been fully recovered. The root cause was a power outage in one of our locations. We don't have information about the exact cause yet but are in contact with the datacenter provider to get more information about the incident. To ensure that a similar incident can be preempted or mitigated, we will do an internal review and inform you about our steps as soon as this has been completed.

    Single Hypervisor Outage

    Início 31 Here 2024 da 09:50 UTC · 3h 6m

    OutageMajor incident
    Componentes afetados
    Cloud server hosts
    1. 31 Here 2024 da 09:50 UTCinvestigating

      One of our hypervisors became unavailable, we're currently investigating the issue

    2. 31 Here 2024 da 10:31 UTCmonitoring

      The hypervisor has been taken out of service and all services have been distributed to different hypervisors. We're closely monitoring the situation and we'll post postmortem once we have all information on what happened.

    3. 31 Here 2024 da 12:56 UTCresolved

      This incident has been resolved.