    Histórico de interrupções do Servers Australia

    52 Servers Australia incidents · Here 2024 — official updates, affected components, duration and resolution details.

    Voltar ao status atual

    Sydney-Brisbane Intercapital backhaul fibre cut

    Início 20 Mezheven 2026 da 00:46 UTC · 2d 23h

    IssuesMinor incident
    Componentes afetados
    NetworkSydneyBrisbane
    1. 20 Mezheven 2026 da 00:46 UTCidentified

      Engineers are aware of another incident causing disruption to one of our fibre paths between Sydney and Brisbane. No impact is expected as a result of this incident, though it should be noted that capacity between regions will be reduced. The incident occurred at approximately 06:37:08 AEST. No ETR has been provided.

    2. 21 Mezheven 2026 da 01:57 UTCmonitoring

      This connection was restored as of 21:51:03. We will monitor the situation until Monday morning, and provide an update once we are satisfied that the connection is stable.

    3. 22 Mezheven 2026 da 23:53 UTCresolved

      This incident has been resolved.

    Sydney-Brisbane Intercapital backhaul service interruption

    Início 16 Mezheven 2026 da 05:12 UTC · 1d 23h

    IssuesMinor incident
    Componentes afetados
    Equinix SY4NextDC B1NetworkSydneyBrisbane
    1. 16 Mezheven 2026 da 05:12 UTCinvestigating

      Servers Australia are aware of a fibre transmission issue impacting one of our backhaul links between Sydney and Brisbane. The issue has been escalated to our provider who are presently investigating. The issue was observed at approximately 03:52:15 UTC and is still ongoing. No service impact is expected as there are multiple redundant paths available between regions, though it should be noted that capacity and redundancy are reduced at this time.

    2. 16 Mezheven 2026 da 05:24 UTCidentified

      The fibre provider has dispatched a technician to the suspected location of the fault and will provide updates as available. The current ETA is 20:00 AEST and no ETR has been provided until the situation has been assessed.

    3. 16 Mezheven 2026 da 14:16 UTCidentified

      Upstream fibre ops team on site and has identified cable damaged during civil works. Assessment of the situation is continuing and no current ETR is available. We will provide our next update by 10 AM AEST.

    4. 16 Mezheven 2026 da 23:52 UTCidentified

      Upstream provider has advised that there are two breaks that need rejoining and some intermediate cable to be laid before services can be restored. The current ETR is 13:00 AEST, and we will provide updates as available.

    5. 17 Mezheven 2026 da 03:44 UTCmonitoring

      The fibre splicing has been completed and connectivity has been restored as of 12:26:54 AEST. Engineers will monitor the status of the link for stability and errors. Once we are satisfied that this link is stable, we will mark this incident as resolved.

    6. 18 Mezheven 2026 da 04:58 UTCresolved

      Engineers have monitored the status of the link overnight and are satisfied that the connection remains stable. This incident is now resolved.

    Equinix BR1 - Colocation rack switch issue

    Início 26 Mae 2026 da 02:04 UTC · 1d 2h

    Pending
    Componentes afetados
    NetworkEquinix BR1Brisbane
    1. 26 Mae 2026 da 02:04 UTCidentified

      An issue has been identified with a colocation switch in the Equinix BR1 facility, specifically rack BR1:02:040110:0511 which is affecting connectivity to services within this rack. On-site technicians are working on restoring service to this rack, and we will provide updates as available.

    2. 26 Mae 2026 da 02:31 UTCmonitoring

      On-site technicians have replaced failed components and services should be returning to normal. If you continue to experience issues as a result of this incident, feel free to raise a case via the MySAU portal. We will monitor the situation and mark this incident as resolved once we are satisfied the issue is no longer present.

    3. 27 Mae 2026 da 04:44 UTCresolved

      After monitoring overnight, we are satisfied that the issue with this device has been resolved.

    Reduced Network Capacity

    Início 23 Mae 2026 da 06:14 UTC · 1d 17h

    Pending
    Componentes afetados
    MelbourneNetworkSydneyBrisbanePerth
    1. 23 Mae 2026 da 06:14 UTCinvestigating

      We are currently investigating an issue affecting our BGP sessions with one of our IP transit providers, which have temporarily dropped due to an ongoing DDoS attack. Please note that no service impact or downtime is expected. While our network automatically rerouted traffic to ensure continuous uptime, we are currently running at reduced capacity. Our engineering team is actively working to mitigate the attack and restore all sessions as quickly as possible.

    2. 23 Mae 2026 da 06:26 UTCmonitoring

      All affected BGP sessions have been successfully restored, and network capacity has returned to full strength. Our team is currently monitoring the situation closely to ensure ongoing stability and performance.

    3. 24 Mae 2026 da 23:19 UTCresolved

      This incident has been resolved.

    Packet Loss Affecting Some International Connectivity

    Início 23 Mae 2026 da 00:31 UTC · 1d 22h

    Pending
    Componentes afetados
    Network
    1. 23 Mae 2026 da 00:31 UTCinvestigating

      Network engineers have been alerted to packet loss affecting connectivity to our network from some international locations. Further updates will be provided as soon as more information becomes available.

    2. 23 Mae 2026 da 00:55 UTCinvestigating

      Upstream engineers have identified the issue, and are working towards a resolution. While the provider works to resolve this on their side, we are making routing changes within our network to prefer alternate paths and reduce the impact to customers.

    3. 23 Mae 2026 da 02:30 UTCmonitoring

      We have confirmed that packet loss is no longer occurring and are continuing to monitor connectivity to ensure services remain stable before closing this incident.

    4. 23 Mae 2026 da 03:29 UTCidentified

      There appears to be some packet loss to destinations routed via Hetzner cloud in Frankfurt (this includes Hetzner US). Engineers are investigating.

    5. 23 Mae 2026 da 06:20 UTCmonitoring

      The upstream transit provider has advised that the issue has now been resolved. We have confirmed that packet loss is no longer occurring and are continuing to monitor connectivity to ensure services remain stable

    6. 24 Mae 2026 da 23:19 UTCresolved

      This incident has been resolved.

    Reduced Redundancy - Syncom SYD2

    Início 19 Mae 2026 da 12:31 UTC · 11h 8m

    Pending
    Componentes afetados
    SYD2
    1. 19 Mae 2026 da 12:31 UTCinvestigating

      Network engineers have been alerted to the loss of one of our redundant paths connecting the Syncom SYD2 facility to our Sydney SY1 facility. Engineers are investigating No services are expected to be affected by this due to a redundant path in place.

    2. 19 Mae 2026 da 23:39 UTCresolved

      This incident has been resolved.

    Packet Loss Affecting Some International Connectivity

    Início 15 Mae 2026 da 03:23 UTC · 2h 55m

    IssuesMinor incident
    Componentes afetados
    Network
    1. 15 Mae 2026 da 03:23 UTCidentified

      Network engineers have been alerted to packet loss affecting connectivity to our network from some international locations. The issue is believed to be related to a known fault with one of our upstream transit providers. While the provider works to resolve this on their side, we are making routing changes within our network to prefer alternate paths and reduce the impact to customers. Further updates will be provided as soon as more information becomes available.

    2. 15 Mae 2026 da 03:32 UTCmonitoring

      The upstream transit provider has advised that the issue has now been resolved. We have confirmed that packet loss is no longer occurring and are continuing to monitor connectivity to ensure services remain stable before closing this incident.

    3. 15 Mae 2026 da 06:18 UTCresolved

      This incident has been resolved.

    Syncom SYD2 - Rack power disturbance

    Início 16 Ebrel 2026 da 14:30 UTC · 11h 29m

    Pending
    Componentes afetados
    Dedicated ServersSydneySYD2
    1. 16 Ebrel 2026 da 14:30 UTCinvestigating

      Engineers have identified a power issue affecting a single rack in the Syncom SYD2 facility. A technician has been dispatched to the site and will provide an update once the problem has been assessed. If you have any questions or are experiencing any interruption to services and would like to enquire further, please raise a case via the MySAU portal.

    2. 16 Ebrel 2026 da 14:54 UTCidentified

      Technicians have identified an issue with a power supply in this rack which caused circuit breaker trip. The problem server(s) have been disconnected and power has been restored to the rack, and services in this rack should now be coming back online. We will monitor the situation and provide an update once we have confirmed everything is stable.

    3. 16 Ebrel 2026 da 15:21 UTCmonitoring

      Technicians have replaced any failed power supplies and have confirmed the rack remains stable. The situation will be monitored for any changes.

    4. 17 Ebrel 2026 da 01:59 UTCresolved

      This incident has been resolved.

    Network Failure - Equinix SY4

    Início 14 Ebrel 2026 da 04:50 UTC · 1d 0h

    IssuesMinor incident
    Componentes afetados
    Equinix SY4NetworkDedicated ServersSydney
    1. 14 Ebrel 2026 da 04:50 UTCidentified

      Network engineers are aware of a network issue affecting a single top-of-rack switch in the Equinix SY4 data centre, which is impacting some dedicated servers. We are arranging onsite hands to assist further. No restoration time is available at this stage. We will provide further updates as soon as possible.

    2. 14 Ebrel 2026 da 05:14 UTCidentified

      The technician is onsite with replacement hardware. We expect an update within the next 10 minutes.

    3. 14 Ebrel 2026 da 05:25 UTCmonitoring

      The technician has successfully replaced the failed hardware, and connectivity has been restored. Please contact our support team should you still be experiencing issues with your service.

    4. 15 Ebrel 2026 da 05:20 UTCresolved

      This incident has been resolved.

    Fortigate Firewall - Reduced Network Capacity

    Início 12 Meurzh 2026 da 21:15 UTC · 1d 4h

    IssuesMinor incident
    Componentes afetados
    Firewall
    1. 12 Meurzh 2026 da 21:15 UTCinvestigating

      We have had a number of customers advise that they are experiencing network capacity constraints when routing through our Sydney FortiGate Firewall Cluster. We have identified that there is an issue with the device memory and that throughput is constrained. Our Network Operations team has been engaged and they are working with FortiNet support to find the root cause of the issue. Updates to Follow

    2. 12 Meurzh 2026 da 22:11 UTCidentified

      The vendor has identified a possible firmware issue. The Fortinet team is currently working with us to implement a workaround while the root cause is investigated further.

    3. 12 Meurzh 2026 da 22:24 UTCidentified

      To implement the workaround on the Primary Device, we need to failover workloads to the redundant side of this Firewall Cluster. This process should not impact workloads further, but we are issuing a cautionary advisory that there may be a brief disruption when this happens. Once the workaround is put in place, the cluster will be restored to full synchronous HA configuration

    4. 12 Meurzh 2026 da 22:42 UTCidentified

      Firewall switchover has occurred, and the former standby unit is now the primary. Engineers will perform some further diagnostics and then reboot the standby unit to clear the error condition. Further updates will be provided as available.

    5. 12 Meurzh 2026 da 23:11 UTCmonitoring

      Per recommendation from the vendor, we will leave the HA cluster un the current state and monitor the situation further. Services should be operating as normal, and no further switchovers are required. The vendor has confirmed that the issue is resolved in a firmware release that is scheduled for late April. Engineers will monitor the status of the cluster until the firmware update is available, and pre-emptively perform a switchover should the cluster approach the memory consumption threshold recommended by the vendor. If you have any questions or continue to experience issues, please raise a case via the MySAU portal.

    6. 13 Meurzh 2026 da 00:18 UTCmonitoring

      We are currently in the process of promoting the SY3 Firewall HA member back to primary after changes made by our Network Operations Team and the vendor earlier this morning. No customer impact is expected.

    7. 13 Meurzh 2026 da 00:30 UTCmonitoring

      This failover is now complete. Please update or raise a case in the MySAU portal if you are experiencing any further issues.

    8. 14 Meurzh 2026 da 01:36 UTCresolved

      This incident has been resolved.

    Loss of Power - Rack F13 - SYD2 Colocation

    Início 6 Cʼhwevrer 2026 da 02:46 UTC · 45m

    Pending
    Componentes afetados
    SYD2
    1. 6 Cʼhwevrer 2026 da 02:46 UTCidentified

      There was a brief power disruption affecting rack F13 in the SYD2 data centre. Services are currently being restored and are coming back online following the interruption. If you have any services that remain impacted or require assistance, please raise a case via the MySAU.com.au portal and our Support Team will be happy to assist.

    2. 6 Cʼhwevrer 2026 da 03:32 UTCresolved

      This incident has been resolved.

    Sydney FortiGate Firewall

    Início 4 Cʼhwevrer 2026 da 19:17 UTC · 1d 4h

    Pending
    Componentes afetados
    FirewallSydneyCloud Servers
    1. 4 Cʼhwevrer 2026 da 19:17 UTCinvestigating

      We have identified an issue affecting customers with IPsec tunnels terminating on the Sydney FortiGate Firewall cluster. Following scheduled maintenance performed earlier this morning (https://status.mysau.com.au/incidents/5zddznmjtl8h) some IPsec tunnels are currently offline and are not re-establishing as expected. Our network and engineering teams are actively investigating this issue and are working directly with Fortinet Support to restore affected services as quickly as possible. At this time, only customers with IPsec tunnels in Sydney are impacted. Other services remain operational. Further updates will be provided as more information becomes available.

    2. 4 Cʼhwevrer 2026 da 20:19 UTCidentified

      Our network and engineering teams have identified a number of configuration inconsistencies following the firmware update performed earlier this morning. We are currently preparing to roll back the firmware update and restore the firewall configuration from backup in order to return service stability and consistency. This rollback will cause a service outage of up to 10 minutes while the configuration is reloaded. The rollback is scheduled to start between 7:30 AM and 08:00 AM Further updates will be provided as work progresses.

    3. 4 Cʼhwevrer 2026 da 20:56 UTCidentified

      We are currently working with FortiGate support to reload the Firewalls in Sydney. Some customers may be experiencing intermittent connectivity loss at this time.

    4. 4 Cʼhwevrer 2026 da 21:20 UTCidentified

      After advice from FortiGate, we have been able to successfully reload one side of the HA FortiGate Firewall Cluster. We are reloading the opposite side now; there will be a brief outage of all traffic while this happens. The outage is expected to be 5-7 minutes Updates to follow

    5. 4 Cʼhwevrer 2026 da 21:45 UTCidentified

      The reload of the other side of the Fortigate Firewall cluster has not resulted in full connectivity for all services. Our Network and System Engineers are still reviewing this and we will update once we have further information.

    6. 4 Cʼhwevrer 2026 da 21:48 UTCidentified

      Most services have now been restored following the rollback and configuration restore. VPS Connectivity has been restored One final firewall reload is required to complete the work. During this reload, customers may experience a brief service interruption. Further updates will be provided shortly.

    7. 4 Cʼhwevrer 2026 da 22:10 UTCmonitoring

      All services have been restored. Firewall configurations have been restored from the backup taken prior to this morning's scheduled maintenance. The firewall cluster is now in sync, and all customer workloads are back online. Both firewalls are now running the latest firmware version. No further downtime is expected.

    8. 5 Cʼhwevrer 2026 da 23:25 UTCresolved

      This incident has been resolved.

    Power issue, site on generator - Equinix SY1

    Início 23 Genver 2026 da 13:38 UTC · 2h 4m

    Pending
    Componentes afetados
    SydneyEquinix SY1
    1. 23 Genver 2026 da 13:38 UTCinvestigating

      We have observed an issue with power affecting the Equinix SY1 facility at approximately 00:15 AEDT. The current status from the facility team indicates that the site is partially running on generator. Engineers are currently investigating the impact while we await further information Further updates will be provided as available. If you have any questions please raise a case via the MySAU portal.

    2. 23 Genver 2026 da 15:17 UTCmonitoring

      The the grid supplier for the site has provided an estimated time of 3:30 AEDT for restoration of the utility supply. The site team have confirmed that all loads remain fully operational on generator until the utility supply is restored. Further updates will be provided as they are made available.

    3. 23 Genver 2026 da 15:42 UTCresolved

      The Equinix SY1 site team have provided an update to confirm that the site is once again running on utility supply. All services remain operational. If you have any questions please raise a case via the MySAU portal.

    Power Outage: Wyong SYD2

    Início 12 Genver 2026 da 03:46 UTC · 6h 6m

    MaintenanceMaintenance event
    Componentes afetados
    SYD2
    1. 12 Genver 2026 da 03:46 UTCmonitoring

      At 1:14 PM AEDT on 12/01/2026, a brief power event occurred due to a power fluctuation affecting a subset of servers on the B-side power rail. As a result, a small number of servers experienced a very short interruption while they automatically rebooted. All servers are now fully online and operating normally. If you are based in SYD2 and are experiencing any ongoing issues with your server, please contact our Support Team by lodging a case via the MySAU.com.au portal, and we will be happy to assist.

    2. 12 Genver 2026 da 09:51 UTCresolved

      This incident has been resolved.

    Reduced Redundancy - Equinix PE2

    Início 10 Genver 2026 da 11:46 UTC · 3d 17h

    IssuesMinor incident
    Componentes afetados
    Equinix PE2NetworkPerth
    1. 10 Genver 2026 da 11:46 UTCidentified

      We have been alerted to a fault affecting one of our upstream transit connections in the Equinix PE2 data centre. The issue has been escalated to the upstream provider for further investigation. No services are currently impacted, as traffic has successfully failed over to our secondary transit provider. Network redundancy is currently reduced while this issue is being investigated.

    2. 10 Genver 2026 da 11:50 UTCidentified

      Our upstream provider has confirmed that this is related to an unscheduled outage on their end and are currently investigating. Further updates will be provided as we hear from them.

    3. 11 Genver 2026 da 00:19 UTCmonitoring

      The upstream provider has resolved the incident. We will monitor for 24 hours before setting this incident to resolved.

    4. 11 Genver 2026 da 02:15 UTCidentified

      Our session with this provider is still continuing to flap. We've reached out to them again advising this and are awaiting a response.

    5. 11 Genver 2026 da 09:21 UTCidentified

      Our upstream provider has advised that the root cause of the service outage has been identified and a replacement unit is being prepared to resolve the issue. They expect service restoration by 10.00 AM AEDT 12/01/2026, though this timeframe remains subject to change. We will provide further updates when possible.

    6. 11 Genver 2026 da 22:41 UTCmonitoring

      Our provider has confirmed that service has been restored. As such, we've re-enabled our sessions, and they have established again. We will continue to monitor this for 24 hours before marking this incident as resolved.

    7. 14 Genver 2026 da 05:45 UTCresolved

      This incident has been resolved.

    Loss of Networking - BR1:Rack 0508

    Início 23 Kerzu 2025 da 02:18 UTC · 5h 39m

    Pending
    Componentes afetados
    Equinix BR1
    1. 23 Kerzu 2025 da 02:18 UTCmonitoring

      A customer in the shared colocation environment caused a broadcast storm due to a network loop within their equipment. This resulted in a brief network disruption affecting the shared switch for rack 0508. The affected switch port has been administratively disabled to isolate the issue. Network connectivity has now been fully restored to the edge switch in rack 0508. Our team is monitoring the environment to ensure continued stability. The customer has been advised on remediation steps to prevent recurrence.

    2. 23 Kerzu 2025 da 07:56 UTCresolved

      Our Network Engineers have continued to monitor the affected switch throughout the day, with no further issues reported. Network services remain stable, and the incident is confirmed as resolved.

    Servers Australia Portal Connectivity Issues

    Início 10 Kerzu 2025 da 01:47 UTC · 57m

    OutageMajor incident
    Componentes afetados
    MySAU Customer Portal
    1. 10 Kerzu 2025 da 01:47 UTCinvestigating

      Engineers are currently aware of connectivity issues affecting our MySAU / Servers Australia Customer Portal. Customers may have difficulty loading the pages and logging into their Servers Australia accounts. Further updates will be provided as soon as possible

    2. 10 Kerzu 2025 da 02:44 UTCresolved

      Engineers have since resolved the issues relating to MySAU Portal connectivity, customers will be able to access their accounts and Support ticketing systems as normal. Customers who are still experiencing issues relating to this may need to clear their browser cache / use a Private Browsing session or alternative device, otherwise feel free to contact our Support team for assistance.

    Edge firewall issue

    Início 9 Kerzu 2025 da 18:48 UTC · 1d 4h

    MaintenanceMaintenance event
    Componentes afetados
    Virtual Data Centre (VDC)Sydney
    1. 9 Kerzu 2025 da 18:48 UTCinvestigating

      We have been alerted by our monitoring to some issues with some traffic passing through the Edge firewalls, which is affecting some Virtual Datacentre customers. We are investigating further.

    2. 9 Kerzu 2025 da 19:36 UTCinvestigating

      We are continuing to investigate this issue with our Engineering team.

    3. 9 Kerzu 2025 da 20:51 UTCmonitoring

      Our engineers identified a large amount of outbound traffic coming from the VDC edge networking services. This traffic caused the edge to become intermittently unavailable for some customers. The offending network has been identified and isolated. All services have been restored. Please log a case in the MySAU portal if you are still experiencing issues.

    4. 10 Kerzu 2025 da 23:40 UTCresolved

      There have been no further disruptions, and this incident has been resolved.

    Process Crash on Sydney Routers

    Início 9 Kerzu 2025 da 04:09 UTC · 6h 37m

    IssuesMinor incident
    Componentes afetados
    Equinix SY4Equinix SY3NetworkSydneyEquinix SY1
    1. 9 Kerzu 2025 da 04:09 UTCinvestigating

      Network engineers are investigating a process crash affecting BGP on our Sydney routers. We believe that services should be operational and that this was just a momentary interruption. Further updates will be provided ASAP.

    2. 9 Kerzu 2025 da 04:39 UTCmonitoring

      Engineers have confirmed that the BGP process is stable, though we will continue to monitor the situation.

    3. 9 Kerzu 2025 da 10:46 UTCresolved

      We believe this to have been the result of a software bug and as such will be scheduling firmware updates in the new year post embargo for these devices.

    Equinix PE2 - Reduced transit redundancy

    Início 9 Kerzu 2025 da 03:19 UTC · 2h 55m

    Pending
    Componentes afetados
    Equinix PE2NetworkPerth
    1. 9 Kerzu 2025 da 03:19 UTCmonitoring

      Engineers have identified an optical module in a pre-failure state and are working with technicians to replace the module. The module being replaced is used to connect to one of our upstream transit providers. No interruption to service is expected, though redundancy will be reduced until this work is completed. We will provide further updates as available, and set this status to resolved when work is concluded.

    2. 9 Kerzu 2025 da 06:14 UTCresolved

      Whilst replacing the optic the technician inadvertently caused an interruption to traffic for services within Equinix PE2. We have resolved the connectivity issue and postponed additional works regarding this module replacement. The approximate window was between 05:39:05 and 05:46:00 UTC +0. If you experienced any issues during this period or have any questions, please get in contact with our Support team.