    Störungsverlauf von Cloudamqp

    58 Cloudamqp incidents · Dezember 2024 — official updates, affected components, duration and resolution details.

    Zurück zum aktuellen Status

    Connection issues in Azure southeast Asia region

    Beginn 21. Oktober 2026 um 16:39 UTC · 34m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 21. Oktober 2026 um 16:39 UTCinvestigating

      We're investigating connectivity issues affecting some servers in Azure West Europe. We'll post an update as soon as we know more.

    2. 21. Oktober 2026 um 17:13 UTCresolved

      Connectivity to servers in southeast Asia has been restored.

    Verbindungsprobleme bei Google europe-west2

    Beginn 20. Oktober 2026 um 07:21 UTC · 6h 11m

    Pending
    Betroffene Komponenten
    Google Cloud Platform Google Compute EngineDedicated servers
    1. 20. Oktober 2026 um 07:21 UTCinvestigating

      Wir untersuchen Verbindungsprobleme, die einige Server in Google europe-west2 betreffen. Wir werden ein Update veröffentlichen, sobald wir mehr wissen.

    2. 20. Oktober 2026 um 07:22 UTCinvestigating

      Wir werden dieses Problem weiter untersuchen.

    3. 20. Oktober 2026 um 07:29 UTCinvestigating

      Incident ist auf Server in europe-west2-b beschränkt

    4. 20. Oktober 2026 um 09:00 UTCmonitoring

      GCE meldet immer noch Probleme, aber wir sehen, dass einige API-Aufrufe erfolgreich sind.

    5. 20. Oktober 2026 um 12:13 UTCmonitoring

      GCE hat bestätigt, dass ein Stromausfall in europe-west2-b die Störung verursacht hat. Das Stromproblem wurde gemildert, und die vollständige Wiederherstellung der betroffenen Workloads wird vorläufig bis heute 13:00 Uhr UTC erwartet. Wir beobachten weiterhin die Erholung.

    6. 20. Oktober 2026 um 12:33 UTCmonitoring

      Wir werden weiterhin auf weitere Probleme achten.

    7. 20. Oktober 2026 um 13:32 UTCresolved

      Dieser Vorfall wurde behoben.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    Konnektivitätsprobleme in Azure West Europe

    Beginn 9. Oktober 2026 um 13:28 UTC · 5h 59m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 9. Oktober 2026 um 13:28 UTCinvestigating

      Wir untersuchen Verbindungsprobleme, die einige Server in Azure West Europe betreffen. Wir werden ein Update veröffentlichen, sobald wir mehr wissen.

    2. 9. Oktober 2026 um 14:39 UTCinvestigating

      Azure ist sich dieses Problems bewusst und untersucht aktiv. Wir werden ein weiteres Update veröffentlichen, sobald wir mehr wissen.

    3. 9. Oktober 2026 um 15:08 UTCidentified

      Azure hat dieses Problem erkannt. Sie haben das Problem auf die Zugänglichkeit von Speichern in der Region eingeengt. Ihre Teams führen aktiv Wiederherstellungsmaßnahmen für die betroffene Infrastruktur durch und untersuchen gleichzeitig die zugrunde liegende Ursache. Wir überwachen den Fortschritt der Erholung und arbeiten daran, die betroffenen Ressourcen wiederherzustellen.

    4. 9. Oktober 2026 um 17:07 UTCmonitoring

      Wir konnten die Kommunikation mit Instanzen in Azure West Europe herstellen. Die meisten Instanzen sind wieder in Betrieb. Azure hat noch einige VMs zu lösen.

    5. 9. Oktober 2026 um 19:27 UTCresolved

      Alle CloudAMQP-Instanzen sind in Azure West Europe aktiv.

    6. 12. Oktober 2026 um 14:51 UTCpostmortem

      **Zusammenfassung** CloudAMQP verlor die Konnektivität mit einer Teilmenge von Clustern in Azure west Europe Availability Zone 2 am 9. Oktober. Einzelne Knotencluster in AZ2 waren am stärksten von dem Vorfall betroffen. **Auswirkungen** Kunden konnten nicht auf Daten zugreifen oder Knoten verwalten, die während des Vorfalls betroffen waren. Zeitleiste der Ereignisse aus Azure. * 12:25 UTC am 09. Oktober 2026 - Wir haben dieses Problem über unsere internen Service-Überwachungsalarme identifiziert. * 12:29 UTC am 09. Oktober 2026 – Die Auswirkungen des Kunden begannen, als VM-Festplattenausfälle in der betroffenen Einheit im westeuropäischen Speicher erkannt wurden. * 2:30 UTC am 9. Oktober 2026 – Die Untersuchung identifizierte einen Verlust des Herzschlags über mehrere Speicherknoten und Fehlerdomänen, was dazu führte, dass die Speicherskalaeinheit in den Notmodus ging. 15:32 UTC am 09. Oktober 2026 - Wir haben die Storage Scale Unit aus dem Distress-Modus genommen und die Festplatten auf den betroffenen Storage-Servern isoliert, um die Wiederherstellung der verbleibenden Festplatten zu ermöglichen. Zu diesem Zeitpunkt begannen die meisten betroffenen Kunden, eine Erholung zu sehen. * 21:00 UTC am 09. Oktober 2026 - Datacenter- und Storage-Ingenieure führten den Wiederherstellungsplan auf mehreren Speicherknoten weiter aus. 23:27 UTC am 09. Oktober 2026 – Die Bemühungen, die betroffenen Speicherknoten wiederherzustellen, waren erfolgreich, und die Arbeiten zur Wiederherstellung der virtuellen Festplatten wurden fortgesetzt. Nachfolgende Wiederherstellungsmaßnahmen umfassten die Wiederherstellung und Wiederherstellung der betroffenen Speicherressourcen auf Knotenebene. * 03:00 UTC am 10. Oktober 2026 – Die Service-Funktionalität wurde wiederhergestellt und die Kundenauswirkungen wurden gemindert. **Wurzelursache** Azure hatte ein Plattformproblem, das zu Auswirkungen auf Azure Virtual Machines-Speicherplatten in der westeuropäischen Region AZ 2 führte. Betroffene Kunden haben möglicherweise Verbindungsfehler, unerwartete Neustarts oder virtuelle Maschinen erlebt, die in einen fehlerhaften Zustand in der Region geraten sind. **Resolution** Der Maschinenzugriff wurde von Azure in etwa 3 Stunden wiederhergestellt. CloudAMQP konnte die Kommunikation mit den betroffenen Knoten wiederherstellen. Wir haben weiterhin Updates von Azure überwacht, um sicherzustellen, dass Knoten nicht mehr betroffen sind.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    Degradierte Managementverbindung zu Azure UAE North

    Beginn 6. Oktober 2026 um 14:37 UTC · 1h 11m

    Pending
    1. 6. Oktober 2026 um 14:37 UTCidentified

      Wir sehen eine gestörte Netzwerkverbindung zwischen einigen Nicht-Azure-Netzwerken und Azure UAE North (azure-arm::uaenorth), verursacht durch ein Routing-Problem bei einem Upstream-Transit-Provider. Alle Server in der Region sind aktiv und verarbeiten Nachrichten, und Überwachung, Metriken und Protokolle funktionieren wie gewohnt. Kunden, deren Clients sich aus Netzwerken verbinden, die von diesem Routing-Problem betroffen sind, können auch Verbindungszeiten sehen. Wir haben das Problem dem Anbieter gemeldet und leiten unseren eigenen Management-Traffic um ihn herum.

    2. 6. Oktober 2026 um 15:44 UTCmonitoring

      Routing ist wieder normal.

    3. 6. Oktober 2026 um 15:48 UTCresolved

      Dieser Vorfall wurde behoben.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    Probleme mit Shared Server 'Seal'

    Beginn 26. August 2026 um 13:27 UTC · 29m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Shared servers
    1. 26. August 2026 um 13:27 UTCinvestigating

      Wir untersuchen derzeit dieses Problem.

    2. 26. August 2026 um 13:28 UTCidentified

      Das Problem wurde identifiziert und ein Fix wird implementiert.

    3. 26. August 2026 um 13:41 UTCmonitoring

      Ein Fix wurde implementiert und wir überwachen die Ergebnisse.

    4. 26. August 2026 um 13:57 UTCresolved

      Dieser Vorfall wurde behoben.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    DigitalOcean Control Panel und API-Ausfall

    Beginn 24. August 2026 um 23:52 UTC · 1d 0h

    Pending
    Betroffene Komponenten
    DigitalOcean AMS3DigitalOcean LON1DigitalOcean NYC2DigitalOcean SFO1DigitalOcean TOR1DigitalOcean SGP1DigitalOcean NYC3DigitalOcean FRA1DigitalOcean AMS2
    1. 24. August 2026 um 23:52 UTCmonitoring

      DigitalOcean hat derzeit Probleme mit seiner API und dem Control Panel und Sie können auf Fehler und höhere Latenz stoßen, während das Problem weiterhin besteht

    2. 25. August 2026 um 23:58 UTCresolved

      Dieser Vorfall wurde behoben.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    Server nicht erreichbar - Azure West US

    Beginn 23. Juli 2026 um 15:33 UTC · 6h 15m

    OutageSchwerwiegender Vorfall
    Betroffene Komponenten
    Microsoft AzureDedicated servers
    1. 23. Juli 2026 um 15:33 UTCinvestigating

      Wir haben verschiedene Warnungen erhalten, die uns darüber informieren, dass einige Server auf Azure West US nicht erreichbar sind. Anscheinend scheint dies spezifisch für diese region zu sein, die 25% der server betrifft.

    2. 23. Juli 2026 um 19:50 UTCmonitoring

      Microsoft Azure bestätigte, dass es Netzwerkprobleme in der Region West US gab. Derzeit sind die meisten Server in Betrieb. Wir werden die nächsten Stunden überwachen.

    3. 23. Juli 2026 um 21:48 UTCresolved

      Dieser Vorfall wurde behoben.

    Automatisch aus der offiziellen Störungsmeldung übersetzt.

    False positive server down messages sent

    Beginn 25. Juni 2026 um 14:10 UTC · 1d 0h

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    BackendDedicated servers
    1. 26. Juni 2026 um 08:38 UTCinvestigating

      We are currently investigating this issue.

    2. 26. Juni 2026 um 09:17 UTCidentified

      The issue has been identified and a fix is being implemented.

    3. 26. Juni 2026 um 14:22 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    4. 26. Juni 2026 um 14:44 UTCresolved

      This incident has been resolved.

    5. 29. Juni 2026 um 11:22 UTCpostmortem

      **Summary** Between June 25 and June 26, our monitoring system incorrectly reported some dedicated servers as unreachable and sent "server down" notifications for servers that were in fact operating normally. This was a monitoring-side issue only — no customer servers or services were actually down, and no data or message delivery was affected. **Impact** Affected customers received one or more alerts indicating their dedicated server was down. These alerts were false positives. The servers themselves remained healthy and fully available throughout the incident. **Root cause** Before connecting to a server, our monitoring system performs a network authorization step. A defect in how one component handled a transient network hiccup could leave a monitoring process unable to complete that step, after which it failed to connect to the servers it was responsible for checking. The servers themselves stayed healthy and available throughout — the monitoring process had simply lost its ability to reach them, and reported them as down. **Resolution** We identified the affected monitoring processes, confirmed the root cause in production, and deployed a fix that makes this authorization step resilient to such transient failures and able to recover automatically. After deploying, we monitored the system to confirm that notifications returned to normal. We apologize for the confusion these false notifications may have caused.

    Monitoring Systems — False Alarms

    Beginn 30. Mai 2026 um 22:25 UTC · 13h 4m

    Pending
    1. 30. Mai 2026 um 22:25 UTCmonitoring

      Between 17:30 and 20:00 UTC on 2026-05-30, our server monitoring system generated a large number of false "server_unreachable" alerts. Clusters were operational and healthy throughout this period — no customer data or message delivery was affected. The alerts were caused by a rolling restart of our monitoring service, during which individual monitoring workers went offline mid-cycle and lost state. This caused the workers to report connection timeouts for servers they could no longer reach — even though those servers were fully healthy. We apologize for any concern this may have caused.

    2. 31. Mai 2026 um 11:29 UTCresolved

      This incident has been resolved.

    Connectivity issues in Azure West Europe

    Beginn 23. Mai 2026 um 16:21 UTC · 1h 1m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 23. Mai 2026 um 16:21 UTCinvestigating

      We are investigating connectivity issues affecting some CloudAMQP instances in Azure West Europe. Affected instances may see connection failures or unexpected restarts. The root cause is an ongoing Microsoft Azure platform incident in the West Europe region (started 14:31 UTC, 23 May 2026). Microsoft is investigating.

    2. 23. Mai 2026 um 17:23 UTCresolved

      Resolved — Microsoft has confirmed that the Azure West Europe Virtual Machines incident is resolved. The impact window was 14:09–14:13 UTC on 23 May 2026, during which a limited number of customers may have experienced connection failures or unexpected Virtual Machine restarts. The Azure environment self-healed and the service has been confirmed restored. Affected CloudAMQP instances should now be operating normally.

    System metrics not forwarded to legacy integration

    Beginn 22. Mai 2026 um 03:16 UTC · 1h 34m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Metrics
    1. 22. Mai 2026 um 03:16 UTCinvestigating

      Since around 8pm UTC last night, some metrics are not being forwarded to legacy integration. Prometheus integrations not affected. We are investingating.

    2. 22. Mai 2026 um 04:08 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    3. 22. Mai 2026 um 04:50 UTCresolved

      This incident has been resolved.

    4. 22. Mai 2026 um 13:52 UTCpostmortem

      # Legacy host metrics integrations degraded Incident window: 2026-05-21 18:37 UTC – 2026-05-22 04:05 UTC \(9h 28m\) Affected service: Legacy metric integrations \(CloudWatch, Datadog, Librato, New Relic, Splunk, Stackdriver\). Host metrics affected, not broker metrics, nor was internal monitoring or console graphs. ## Summary For ~9.5 hours, the service that collects host-level metrics \(CPU, memory, disk, network\) for legacy third-party integrations entered a crash loop and stopped shipping data. ## Root Cause An internal credential-signing service was migrated to a new container runtime the afternoon before. Due to a bug with environment variables the collector could not renew it's credentials. The collector's existing credential remained valid for several hours, so the failure only surfaced when it tried to renew. ## Resolution On-call staff detected the failure early morning, developers helped restore the service and collector recovered at 04:05 UTC. ## Prevention * All services, both signing and collector report failed authentication attempts earlier and with higher severity * Metrics pipeline alarm thresholds was tightened so a similar drop in data triggers alarms faster.

    Backend slow

    Beginn 19. Mai 2026 um 13:21 UTC · 28m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Backend
    1. 19. Mai 2026 um 13:21 UTCinvestigating

      We are currently experiencing issues with our backend services handling account and server creation. This does not affect any running customer servers but might delay provisioning new servers.

    2. 19. Mai 2026 um 13:36 UTCidentified

      The issue has been identified and a fix is being implemented.

    3. 19. Mai 2026 um 13:41 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    4. 19. Mai 2026 um 13:50 UTCresolved

      This incident has been resolved.

    Backend slow

    Beginn 5. Mai 2026 um 10:23 UTC · 3h 0m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Backend
    1. 5. Mai 2026 um 10:23 UTCinvestigating

      We are currently experiencing issues with our backend services handling account and server creation. This does not affect any running customer servers but might delay provisioning new servers.

    2. 5. Mai 2026 um 10:41 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    3. 5. Mai 2026 um 11:23 UTCmonitoring

      Still seeing slow requests, doing another investigation.

    4. 5. Mai 2026 um 11:34 UTCmonitoring

      Looks like we're back at full performance now.

    5. 5. Mai 2026 um 13:23 UTCresolved

      This incident has been resolved.

    Connecting issues in Azure West Europe

    Beginn 3. Mai 2026 um 19:11 UTC · 6h 34m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 3. Mai 2026 um 19:11 UTCinvestigating

      We are currently investigating this issue.

    2. 3. Mai 2026 um 19:14 UTCidentified

      Servers in Azure West Europe can experience connection issues due to underlying issues at provider. Latest update from Azure "Current Status: We continue to investigate an availability issue caused by a subset of unhealthy backend storage infrastructure supporting Azure Virtual Machines and Azure Direct Drive in West Europe."

    3. 4. Mai 2026 um 01:44 UTCresolved

      This incident has been resolved.

    Backend slow/unresponsible

    Beginn 28. April 2026 um 10:27 UTC · 38m

    OutageSchwerwiegender Vorfall
    Betroffene Komponenten
    Backend
    1. 28. April 2026 um 10:27 UTCinvestigating

      We are currently experiencing issues with our backend services handling account and server creation. This does not affect any running customer servers but might delay provisioning new servers.

    2. 28. April 2026 um 10:49 UTCidentified

      The issue has been identified and a fix is being implemented.

    3. 28. April 2026 um 10:53 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    4. 28. April 2026 um 11:05 UTCresolved

      We had an abnormal increase in traffic causing timeouts and slow responses for customer.cloudamqp.com, we increased capacity and are back to normal. This did not affect any running clusters, just provisioning and configuration updates.

    Connection issues in Azure region westus

    Beginn 24. April 2026 um 09:36 UTC · 29m

    OutageSchwerwiegender Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 24. April 2026 um 09:36 UTCinvestigating

      We are getting indications of instances being down in Azure region westus. We are investigating the issue.

    2. 24. April 2026 um 11:12 UTCresolved

      This incident has been resolved.

    Issues with Azure West US 3 region

    Beginn 23. April 2026 um 10:10 UTC · 45m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Microsoft Azure
    1. 23. April 2026 um 10:10 UTCinvestigating

      Servers in Azure West US 3 can experience connection issues due to underlying issues at provider. We monitor and will update when we know more.

    2. 23. April 2026 um 10:56 UTCresolved

      This incident has been resolved.

    Metrics integration issues

    Beginn 23. April 2026 um 03:30 UTC · 2h 30m

    Pending
    Betroffene Komponenten
    Metrics
    1. 23. April 2026 um 04:33 UTCinvestigating

      There appears to be an issue regarding sending metrics to all Legacy metrics integrations. Alarms based on broker metrics also got affected. We are currently investigating the issue Prometheus based metrics (Datadog v3 etc) not affected.

    2. 23. April 2026 um 06:53 UTCmonitoring

      A fix has been implemented and we are monitoring the results.

    3. 23. April 2026 um 11:32 UTCresolved

      This incident has been resolved.

    4. 24. April 2026 um 08:38 UTCpostmortem

      Broker metrics and metrics integrations degradation Window: 2026-04-23 03:25 – 05:35 UTC \(2h 10m\) ## Impact Broker metrics \(connections, channels, queues, consumers, message rates, node and netsplit state\) were degraded, progressively dropping until recovery at 05:35 UTC. Downstream effects: * Queue, Consumer, Connection, Channel, Connection flow, and Netsplit alarms: threshold breaches during the window may not have triggered, or triggered late. Alarms already tripped before 03:25 UTC kept their state. * Metrics Integrations \(Datadog, CloudWatch, New Relic, Splunk, Dynatrace, etc.\): delivery of broker metrics was reduced for the duration of the window. Alarms configured on the receiving side may likewise have missed or lagged. Not affected: server metrics \(CPU, memory, disk\) and their corresponding alarms, Notice alarms, broker availability, and the metric graphs shown in the CloudAMQP console \(these use a separate data path and continued to update normally\). ## Timeline \(UTC\) * 03:25 — broker-metrics collection begins degrading * 03:35 — ~30% of broker-metric samples missing * 03:50 — ~50% plateau * 05:25 — collector workers cycled and re-initialised * 05:35 — full throughput restored ## Root cause Broker metrics are polled from each cluster's management HTTP API by a pool of collector workers and published to an internal message bus that both the Alarms service and Metrics Integrations consume from. At 03:25 UTC this service became unresponsive without raising an error. Affected workers silently stopped polling while remaining alive to the platform, so automatic restart did not trigger. On-call staff began investigating around 05:00 UTC; force-restarting the service restored metric flow. The exact trigger has not been identified. Our focus is on ensuring the condition is detected and handled promptly if it recurs. ## What we are changing * Added metrics and alarms specific to this service, with high-urgency paging for on-call. * Reliability improvements in the service itself to detect and restart stalled work. ## What you can do CloudAMQP offers a new generation of metrics integrations based on Prometheus, with a re-engineered pipeline that does not rely on these centralised services — each server forwards data directly to your endpoint. These have been running in production for some time and have proved very reliable. * [https://www.cloudamqp.com/blog/prometheus-metrics-integrations.html](https://www.cloudamqp.com/blog/prometheus-metrics-integrations.html) * [https://www.cloudamqp.com/docs/monitoring\_metrics\_datadog\_v3.html](https://www.cloudamqp.com/docs/monitoring_metrics_datadog_v3.html) * Background: [https://www.cloudamqp.com/blog/decentralized-observability-with-open-telemetry-part-1.html](https://www.cloudamqp.com/blog/decentralized-observability-with-open-telemetry-part-1.html)

    Monitoring Systems Short Outage and "Connection issues" Alarms

    Beginn 15. April 2026 um 14:00 UTC · 0m

    Pending
    1. 15. April 2026 um 15:32 UTCresolved

      One of our backend components suffered a small outage due to an unexpected full services restart. Connectivity with the servers were broken and service triggered alarms for many clusters. We apologize for the inconvenience. All clusters were operational and healthy within the incident/alarms timespan.

    Management Interface Unavailable - 502 Bad Gateway Response

    Beginn 2. April 2026 um 14:41 UTC · 31m

    IssuesGeringfügiger Vorfall
    Betroffene Komponenten
    Shared serversDedicated servers
    1. 2. April 2026 um 14:41 UTCidentified

      Customers are experiencing Management UI being unavailable with 502 Bad Gateway. Timeline: - 14:16 UTC -> The issue was identified - 14:30 UTC -> Recent code changes were reverted. No relationship with incident noted.

    2. 2. April 2026 um 14:52 UTCidentified

      The Management UI and brokers are serving traffic normally. You can still use the Management UI by using the Broker URL and properly typing User and Password. The impact is related to our backend service logs into Management UI via CloudAMQP SSO.

    3. 2. April 2026 um 15:07 UTCidentified

      We are continuing to work on a fix for this issue.

    4. 2. April 2026 um 15:12 UTCresolved

      The Management UI SSO shortcut is back to service. Impacted Clusters: All customers with clusters created more than 6 months ago Cause: Some code changes unexpectedly changed the communication schema between our backend services and the SSO component on the clusters. The proxy configuration conflicted with those changes causing the 502 Bad Gateway error to show up. Impact: Only the SSO via CloudAMQP Console was impacted given it required communication with our backend components. The AMQP Clusters were healthy and servicing traffic via both AMQP and HTTP on Management UI and API. Logging into the Management UI via Credentials and all Authentications Backends was functioning normally.