Our upstream provider at our Zurich cloud environment, has confirmed network issues. They are currently investigating and we will provide updates as soon as available here.
Link to our upstream‘s status page: https://status.nine.ch/
resolved
We have been informed that the incident is resolved since 9.06pm.
Perdita di pacchetto su alcuni ipervisori
Inizio 22 luglio 2026 alle ore 09:20 UTC · 7h 55m
IssuesIncidente minore
Componenti interessati
Cloud server hosts
investigating
Stiamo attualmente indagando su questo problema.
identified
Il problema è stato identificato e si sta attuando una correzione.
resolved
L'incidente è stato completamente risolto.
Tradotto automaticamente dall'aggiornamento ufficiale dell'incidente.
Brief network disturbance in Frankfurt (FRA) during scheduled maintenance
Inizio 23 giugno 2026 alle ore 16:40 UTC · 0m
OutageIncidente maggiore
resolved
During scheduled maintenance on our network infrastructure on Jun 23, 2026, one of our edge routers in Frankfurt (FRA) became temporarily unavailable by a software overload. This caused a network interruption of approximately one minute, until the second edge router fully took over the routing and connectivity was restored.
Although the maintenance was announced, no service impact was expected. The disturbance was briefly wider than the announced scope, affecting connectivity for most of services in the Frankfurt location rather than only the one announced VLAN.
We stopped the change immediately and have paused the remaining maintenance while we review the underlying causes, so the work can be completed reliably. We apologize for the any circumstances.
Upstream packet loss
Inizio 19 giugno 2026 alle ore 09:46 UTC · 2h 49m
Pending
Componenti interessati
Core Network
identified
We have identified packet loss to one of our upstream providers, routes have been switched. We will be monitoring the situation.
resolved
The issue was caused by unstable firmware on the core router of one of our upstream providers. The firmware has now been updated, and the routes have been returned to their previous state.
Info: DENIC Outage
Inizio 5 maggio 2026 alle ore 21:41 UTC · 9h 54m
OutageIncidente critico
Componenti interessati
DENIC
identified
The DENIC is currently experiencing a major issue causing all .de Domains to become unresolvable after dns caches run out.
DENIC Statuspage: https://status.denic.de/pages/incident/592577eab611ce1e0d00046f/69fa60ef9d12f5057a974f38
resolved
This incident has been resolved.
Service degration at ZRH1 (Zurich datacenter)
Inizio 12 marzo 2026 alle ore 17:21 UTC · 3m
IssuesIncidente minore
Componenti interessati
Cloud server hosts
investigating
During routine maintenance work, we encountered a service degration at our Zurich datacenter, which affects one hypervisor and the VM's running on it.
We are currently investigating this issue and keep you updated here.
resolved
The issue has been identified and resolved.
MySQL database outage
Inizio 10 marzo 2026 alle ore 10:13 UTC · 2h 2m
OutageIncidente critico
Componenti interessati
Cloud server hosts
investigating
At March 10, 2026, 11:13 AM, our monitoring alerted that the customer MySQL database was not available. The issue affects managed web hosting services which are operated within our Kubernetes clusters.
investigating
We are still investigating an issue with the VM's running the database.
resolved
The incident has been resolved and the environments are all available again. We will provide further information with our postmortem.
Packet-loss during SDN configuration changes
Inizio 7 marzo 2026 alle ore 22:00 UTC · 16m
Pending
resolved
We encountered packet loss on virtual machines during a network reload in our virtualization environment when provisioning new SDN settings. The issue was resolved by March 8, 2026, 0:30.
Moving forward, we will implement measures to ensure that network reloads do not cause packet loss. We will therefore announce the according maintenance frame here on the statuspage.
Network outage
Inizio 16 febbraio 2026 alle ore 18:15 UTC · 1h 16m
OutageIncidente critico
Componenti interessati
Core Network
investigating
We are currently experiencing a network outage at our location in Frankfurt. We are currently investigating and provide updates on this page as soon as possible.
identified
The network is available again since 19:24 CET. We continue investigating and analyzing the route cause.
resolved
The incident has been resolved and no further impact is expected. We will provide details today afternoon.
postmortem
On February 16, 2026, an incident identified as INC-262 occurred, resulting in a critical network outage that affected all systems in our Frankfurt data centers for a duration of 8 minutes.
The incident was triggered by a routine configuration change made to a static route on one of our routers. Prior to implementation, the configuration underwent validation via the operating system \(Juniper Junos OS\), which generally checks for errors. However, due to a bug in the firmware, the system incorrectly accepted a faulty configuration change.
4 minutes after the change was applied, both forwarding engines were reported unreachable by the routing engine. The issue was promptly detected and reported by our monitoring systems. An automatic rollback occurred one minute following the failure due to a lack of manual confirmation, which restored both routing engines and forwarding engines. Safety mechanisms have worked as expected and resulted in a quick recovery completed by 7:27 PM.
To preemptively harden our infrastructure against similar issues in the future, we already planned to transition from a redundant routing chassis to completely isolated devices, ensuring full redundancy even in case of such failures. This transition is scheduled for April/May during a planned maintenance. We appreciate your understanding and patience as we work to enhance our systems' reliability.
Degraded connectivity between our locations at FRA and ZUR
Inizio 11 febbraio 2026 alle ore 12:30 UTC · 0m
IssuesIncidente minore
resolved
At 1:28PM the connection between our locations in Frankfurt and Zurich become degraded since one gateway at our upstreams becomes unavailable. The issue was resolved by 1:49PM completely by changing the gateway's configuration and adapting to the new configuration. Moving forward, we will check for possible improvements to enhance network resilience.
Packet-loss on carrier-level
Inizio 23 gennaio 2026 alle ore 08:00 UTC · 0m
IssuesIncidente minore
resolved
Starting this morning, we have detected packet loss occurring a few times for a few seconds at carrier level. Our analysis revealed that this is related to incoming or outgoing traffic via Liberty Global (AS6830).
As a mitigation measure, we have deactivated this carrier and are using alternative routes. We will monitor the situation closely and wait for a response before reactivating the carrier.
Upstream BGP Session Restart (No Impact)
Inizio 26 novembre 2025 alle ore 09:50 UTC · 1h 0m
Pending
resolved
One of our upstreams was experiencing network issues for about 5 minutes. Redundancy was working as expected and there was no noticeable impact.
Hardware network link failure in FRA-2
Inizio 11 novembre 2025 alle ore 11:34 UTC · 1h 0m
Pending
resolved
A physical network connection inside our network in our FRA-2 location failed causing packet loss and a disturbance of multiple services. All our links are setup redundantly and the redundancy automatically took over within a few seconds.
Packet loss via routes of AS48314
Inizio 4 ottobre 2025 alle ore 11:51 UTC · 29m
Pending
Componenti interessati
Core Network
investigating
One of our uplink providers, IP-Projects (AS48314), is experiencing a network attack. This have lead to packet loss for max. five minutes, starting from 11.42. We have deactivated incoming and outgoing till the network is stable again there.
Link to our uplink's status page entry: https://status.ip-projects.de/?page=Issue&id=551
resolved
This incident has been resolved.
Network disturbance during active DDoS mitigation
Inizio 23 luglio 2025 alle ore 07:00 UTC · 0m
Pending
resolved
From 22 July 2025 10pm to 23 July 2025 1.30pm, some customers using our DDoS Protected IP-Transit service experienced connectivity issues during active DDoS mitigation. This was due to an incorrect routing configuration by one of our upstream providers.
The incident affected IP addresses with active DDoS mitigations during the mitigation period for the attack (typically 30 minutes). The majority of our services remained operational throughout this period.
We resolved the issue by extending our routing policies and working with our provider to prevent this configuration problem from recurring.
We apologize for any inconvenience this may have caused.
DNS resolution issues caused by Cloudflare DNS unavailability
Inizio 14 luglio 2025 alle ore 22:06 UTC · 1h 13m
IssuesIncidente minore
Componenti interessati
Core Network
investigating
We are seeing issues regarding routes to Cloudflare, we're investigating and will update you as soon as we have further information.
identified
We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it.
identified
We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it.
Cloudflare has posted the incident on their statuspage: https://www.cloudflarestatus.com/incidents/28r0vbbxsh8f
identified
We continuing to monitor
resolved
The incident has been resolved by Cloudflare
Network disturbance at FRA01
Inizio 2 aprile 2025 alle ore 13:00 UTC · 8h 27m
OutageIncidente critico
Componenti interessati
Core Network
investigating
We are currently experiencing network issues at our Frankfurt locations.
monitoring
The network issue has been fixed and our network is stable again. We keep monitoring and will provide updates here.
resolved
This incident has been resolved.
postmortem
At approximately 15:00 CET on April 2nd, 2025, we experienced a brief network disruption affecting our Frankfurt \(FRA\) infrastructure. The incident occurred during a scheduled maintenance window for one of our upstream providers.
The network disruption lasted for approximately seven minutes, during which some of our services experienced reduced accessibility. Our network engineering team identified the issue immediately and implemented necessary measures to restore service stability.
While we typically handle such maintenance windows without any customer impact, this particular incident resulted in a brief service interruption. We have conducted a thorough review of our maintenance procedures and will be implementing additional safeguards to prevent similar incidents in the future.
We understand the impact this may have had on your operations and apologize for any inconvenience caused. Our team remains committed to providing reliable service and continuous improvement of our infrastructure management processes.
If you have any questions or concerns, please don't hesitate to reach out to us.
Major outage of our compute infrastructure in FRA-2
Inizio 5 dicembre 2024 alle ore 13:54 UTC · 19h 47m
OutageIncidente critico
Componenti interessati
Cloud server hosts
investigating
We're currently experiencing a major outage on our compute infrastructure in our FRA-2 location. We're investigating the issue and will provide additional information soon
identified
We've identified the issue and are working on recovering all services ASAP
identified
We are currently booting all affected servers again. The services will be back online in the next minutes.
monitoring
We brought all services back up and are closely monitoring them
monitoring
All services are running as expected again. We will keep monitoring and let the incident open till we publish an official statement tomorrow.
resolved
All systems and services have been stable since the recovery and the normal operational state has been fully recovered. The root cause was a power outage in one of our locations. We don't have information about the exact cause yet but are in contact with the datacenter provider to get more information about the incident. To ensure that a similar incident can be preempted or mitigated, we will do an internal review and inform you about our steps as soon as this has been completed.
Single Hypervisor Outage
Inizio 31 ottobre 2024 alle ore 09:50 UTC · 3h 6m
OutageIncidente maggiore
Componenti interessati
Cloud server hosts
investigating
One of our hypervisors became unavailable, we're currently investigating the issue
monitoring
The hypervisor has been taken out of service and all services have been distributed to different hypervisors. We're closely monitoring the situation and we'll post postmortem once we have all information on what happened.
resolved
This incident has been resolved.
Network outage in FRA
Inizio 28 settembre 2024 alle ore 06:01 UTC · 1h 21m
OutageIncidente critico
Componenti interessati
Core Network
investigating
We are currently investigating
monitoring
The issue has been mitigated, we continue to monitor and post an update once we have all information on what exactly happened
resolved
This incident has been resolved.
Cronologia delle interruzioni di Lumaserv | Uptimus