Our upstream provider at our Zurich cloud environment, has confirmed network issues. They are currently investigating and we will provide updates as soon as available here.
Link to our upstream‘s status page: https://status.nine.ch/
resolved
We have been informed that the incident is resolved since 9.06pm.
Pérdida de paquete en ciertos hipervisores
Comenzó July 22, 2026 at 9:20 AM UTC · 7h 55m
IssuesMinor incident
Componentes afectados
Cloud server hosts
investigating
Actualmente estamos investigando esta cuestión.
identified
Se ha determinado la cuestión y se está aplicando una solución.
resolved
El incidente se ha resuelto completamente.
Traducido automáticamente desde la actualización oficial del incidente.
Brief network disturbance in Frankfurt (FRA) during scheduled maintenance
Comenzó June 23, 2026 at 4:40 PM UTC · 0m
OutageMajor incident
resolved
During scheduled maintenance on our network infrastructure on Jun 23, 2026, one of our edge routers in Frankfurt (FRA) became temporarily unavailable by a software overload. This caused a network interruption of approximately one minute, until the second edge router fully took over the routing and connectivity was restored.
Although the maintenance was announced, no service impact was expected. The disturbance was briefly wider than the announced scope, affecting connectivity for most of services in the Frankfurt location rather than only the one announced VLAN.
We stopped the change immediately and have paused the remaining maintenance while we review the underlying causes, so the work can be completed reliably. We apologize for the any circumstances.
Upstream packet loss
Comenzó June 19, 2026 at 9:46 AM UTC · 2h 49m
Pending
Componentes afectados
Core Network
identified
We have identified packet loss to one of our upstream providers, routes have been switched. We will be monitoring the situation.
resolved
The issue was caused by unstable firmware on the core router of one of our upstream providers. The firmware has now been updated, and the routes have been returned to their previous state.
Info: DENIC Outage
Comenzó May 5, 2026 at 9:41 PM UTC · 9h 54m
OutageCritical incident
Componentes afectados
DENIC
identified
The DENIC is currently experiencing a major issue causing all .de Domains to become unresolvable after dns caches run out.
DENIC Statuspage: https://status.denic.de/pages/incident/592577eab611ce1e0d00046f/69fa60ef9d12f5057a974f38
resolved
This incident has been resolved.
Service degration at ZRH1 (Zurich datacenter)
Comenzó March 12, 2026 at 5:21 PM UTC · 3m
IssuesMinor incident
Componentes afectados
Cloud server hosts
investigating
During routine maintenance work, we encountered a service degration at our Zurich datacenter, which affects one hypervisor and the VM's running on it.
We are currently investigating this issue and keep you updated here.
resolved
The issue has been identified and resolved.
MySQL database outage
Comenzó March 10, 2026 at 10:13 AM UTC · 2h 2m
OutageCritical incident
Componentes afectados
Cloud server hosts
investigating
At March 10, 2026, 11:13 AM, our monitoring alerted that the customer MySQL database was not available. The issue affects managed web hosting services which are operated within our Kubernetes clusters.
investigating
We are still investigating an issue with the VM's running the database.
resolved
The incident has been resolved and the environments are all available again. We will provide further information with our postmortem.
Packet-loss during SDN configuration changes
Comenzó March 7, 2026 at 10:00 PM UTC · 16m
Pending
resolved
We encountered packet loss on virtual machines during a network reload in our virtualization environment when provisioning new SDN settings. The issue was resolved by March 8, 2026, 0:30.
Moving forward, we will implement measures to ensure that network reloads do not cause packet loss. We will therefore announce the according maintenance frame here on the statuspage.
Network outage
Comenzó February 16, 2026 at 6:15 PM UTC · 1h 16m
OutageCritical incident
Componentes afectados
Core Network
investigating
We are currently experiencing a network outage at our location in Frankfurt. We are currently investigating and provide updates on this page as soon as possible.
identified
The network is available again since 19:24 CET. We continue investigating and analyzing the route cause.
resolved
The incident has been resolved and no further impact is expected. We will provide details today afternoon.
postmortem
On February 16, 2026, an incident identified as INC-262 occurred, resulting in a critical network outage that affected all systems in our Frankfurt data centers for a duration of 8 minutes.
The incident was triggered by a routine configuration change made to a static route on one of our routers. Prior to implementation, the configuration underwent validation via the operating system \(Juniper Junos OS\), which generally checks for errors. However, due to a bug in the firmware, the system incorrectly accepted a faulty configuration change.
4 minutes after the change was applied, both forwarding engines were reported unreachable by the routing engine. The issue was promptly detected and reported by our monitoring systems. An automatic rollback occurred one minute following the failure due to a lack of manual confirmation, which restored both routing engines and forwarding engines. Safety mechanisms have worked as expected and resulted in a quick recovery completed by 7:27 PM.
To preemptively harden our infrastructure against similar issues in the future, we already planned to transition from a redundant routing chassis to completely isolated devices, ensuring full redundancy even in case of such failures. This transition is scheduled for April/May during a planned maintenance. We appreciate your understanding and patience as we work to enhance our systems' reliability.
Degraded connectivity between our locations at FRA and ZUR
Comenzó February 11, 2026 at 12:30 PM UTC · 0m
IssuesMinor incident
resolved
At 1:28PM the connection between our locations in Frankfurt and Zurich become degraded since one gateway at our upstreams becomes unavailable. The issue was resolved by 1:49PM completely by changing the gateway's configuration and adapting to the new configuration. Moving forward, we will check for possible improvements to enhance network resilience.
Packet-loss on carrier-level
Comenzó January 23, 2026 at 8:00 AM UTC · 0m
IssuesMinor incident
resolved
Starting this morning, we have detected packet loss occurring a few times for a few seconds at carrier level. Our analysis revealed that this is related to incoming or outgoing traffic via Liberty Global (AS6830).
As a mitigation measure, we have deactivated this carrier and are using alternative routes. We will monitor the situation closely and wait for a response before reactivating the carrier.
Upstream BGP Session Restart (No Impact)
Comenzó November 26, 2025 at 9:50 AM UTC · 1h 0m
Pending
resolved
One of our upstreams was experiencing network issues for about 5 minutes. Redundancy was working as expected and there was no noticeable impact.
Hardware network link failure in FRA-2
Comenzó November 11, 2025 at 11:34 AM UTC · 1h 0m
Pending
resolved
A physical network connection inside our network in our FRA-2 location failed causing packet loss and a disturbance of multiple services. All our links are setup redundantly and the redundancy automatically took over within a few seconds.
Packet loss via routes of AS48314
Comenzó October 4, 2025 at 11:51 AM UTC · 29m
Pending
Componentes afectados
Core Network
investigating
One of our uplink providers, IP-Projects (AS48314), is experiencing a network attack. This have lead to packet loss for max. five minutes, starting from 11.42. We have deactivated incoming and outgoing till the network is stable again there.
Link to our uplink's status page entry: https://status.ip-projects.de/?page=Issue&id=551
resolved
This incident has been resolved.
Network disturbance during active DDoS mitigation
Comenzó July 23, 2025 at 7:00 AM UTC · 0m
Pending
resolved
From 22 July 2025 10pm to 23 July 2025 1.30pm, some customers using our DDoS Protected IP-Transit service experienced connectivity issues during active DDoS mitigation. This was due to an incorrect routing configuration by one of our upstream providers.
The incident affected IP addresses with active DDoS mitigations during the mitigation period for the attack (typically 30 minutes). The majority of our services remained operational throughout this period.
We resolved the issue by extending our routing policies and working with our provider to prevent this configuration problem from recurring.
We apologize for any inconvenience this may have caused.
DNS resolution issues caused by Cloudflare DNS unavailability
Comenzó July 14, 2025 at 10:06 PM UTC · 1h 13m
IssuesMinor incident
Componentes afectados
Core Network
investigating
We are seeing issues regarding routes to Cloudflare, we're investigating and will update you as soon as we have further information.
identified
We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it.
identified
We identified that Cloudflare DNS has major issues, causing some servers using Cloudflare DNS to have dns resolution issues. This is not an issue on our side but we'll keep monitoring it.
Cloudflare has posted the incident on their statuspage: https://www.cloudflarestatus.com/incidents/28r0vbbxsh8f
identified
We continuing to monitor
resolved
The incident has been resolved by Cloudflare
Network disturbance at FRA01
Comenzó April 2, 2025 at 1:00 PM UTC · 8h 27m
OutageCritical incident
Componentes afectados
Core Network
investigating
We are currently experiencing network issues at our Frankfurt locations.
monitoring
The network issue has been fixed and our network is stable again. We keep monitoring and will provide updates here.
resolved
This incident has been resolved.
postmortem
At approximately 15:00 CET on April 2nd, 2025, we experienced a brief network disruption affecting our Frankfurt \(FRA\) infrastructure. The incident occurred during a scheduled maintenance window for one of our upstream providers.
The network disruption lasted for approximately seven minutes, during which some of our services experienced reduced accessibility. Our network engineering team identified the issue immediately and implemented necessary measures to restore service stability.
While we typically handle such maintenance windows without any customer impact, this particular incident resulted in a brief service interruption. We have conducted a thorough review of our maintenance procedures and will be implementing additional safeguards to prevent similar incidents in the future.
We understand the impact this may have had on your operations and apologize for any inconvenience caused. Our team remains committed to providing reliable service and continuous improvement of our infrastructure management processes.
If you have any questions or concerns, please don't hesitate to reach out to us.
Major outage of our compute infrastructure in FRA-2
Comenzó December 5, 2024 at 1:54 PM UTC · 19h 47m
OutageCritical incident
Componentes afectados
Cloud server hosts
investigating
We're currently experiencing a major outage on our compute infrastructure in our FRA-2 location. We're investigating the issue and will provide additional information soon
identified
We've identified the issue and are working on recovering all services ASAP
identified
We are currently booting all affected servers again. The services will be back online in the next minutes.
monitoring
We brought all services back up and are closely monitoring them
monitoring
All services are running as expected again. We will keep monitoring and let the incident open till we publish an official statement tomorrow.
resolved
All systems and services have been stable since the recovery and the normal operational state has been fully recovered. The root cause was a power outage in one of our locations. We don't have information about the exact cause yet but are in contact with the datacenter provider to get more information about the incident. To ensure that a similar incident can be preempted or mitigated, we will do an internal review and inform you about our steps as soon as this has been completed.
Single Hypervisor Outage
Comenzó October 31, 2024 at 9:50 AM UTC · 3h 6m
OutageMajor incident
Componentes afectados
Cloud server hosts
investigating
One of our hypervisors became unavailable, we're currently investigating the issue
monitoring
The hypervisor has been taken out of service and all services have been distributed to different hypervisors. We're closely monitoring the situation and we'll post postmortem once we have all information on what happened.
resolved
This incident has been resolved.
Network outage in FRA
Comenzó September 28, 2024 at 6:01 AM UTC · 1h 21m
OutageCritical incident
Componentes afectados
Core Network
investigating
We are currently investigating
monitoring
The issue has been mitigated, we continue to monitor and post an update once we have all information on what exactly happened